NDUSTRIA™ NBH Indoor/Outdoor Infrared Straight Gas Heater
Free delivery to contiguous U.S. + free 30-day returns. Est. arrival: Sep 6–16
Best Price Guarantee
Best Price Guarantee
- Lowest Price Online—Guaranteed. If you find the same product for less at another authorized dealer, we’ll beat it.
- Easy to Claim: click here to submit your price match request
- Qualifications: Item must be identical, in stock, new (not refurbished/open-box), and sold by an authorized dealer. Total cost (including shipping & tax) must be lower.
- Peace of Mind: All details you provide are kept completely confidential. We use this information only to verify the price.
Installation
Installation
Need installation support? We’ll help you find a qualified pro.
Request a Quote
Request a Quote
Need a price or shipping estimate? Click here to request a quote.
Photo Gallery
Description
Description
Eight Output Steps, Mounted as High as 25 Feet
A gas-fired low-intensity infrared tube heater from Roberts-Gordon, built for the buildings that are hardest to heat: warehouses, distribution floors, manufacturing space, aircraft hangars, loading docks and vehicle service bays. It also serves a large covered patio well.
Eight outputs, 40,000 to 150,000 BTU. That is a finer ladder than most tube heaters offer, and it matters when you are matching output to a building rather than rounding up. The steps run 40, 60, 80, 100, 115, 125, 140 and 150 thousand BTU, in tube lengths from 10 ft 11 in to 40 ft 11 in.
It mounts higher than the NHE. Recommended mounting height runs from 8 to 10 ft on the smallest unit up to 20 to 25 ft on the largest, against a 20 ft ceiling on the comparable NHE straight tube. In a tall warehouse or a hangar, that extra reach is the deciding difference.
Infrared heat radiates onto the floor, the racking and the people, rather than warming air that would rise straight to a 25 ft ceiling and sit there. In a high-bay building that is not a refinement, it is the whole reason this equipment exists.
Need the same heat in less length? The U-Tube version folds the run roughly in half, 12 ft 6 in to 22 ft 6 in for the same outputs.
Vented or unvented. Unvented outdoors and under open cover. Indoors, vent it through a 4 in flue or supply ventilation air at the code minimum of 4 CFM per 1,000 BTU/hr.
Roberts-Gordon publishes no square-foot rating. These are sized by heat loss calculation against your building and mounting height, and we can help you work it through.
Natural gas or propane, direct spark ignition, CSA and ANSI certified, made in the USA.
Note: Covered and walled spaces, temporary or permanent, may need venting installed.
What's Included: Straight Tube Heater, Reflector, and User's Manual
Do you live in places above 4,000 ft. elevation or need help determining the right heater and setup for your space and heating needs? Give us a call at (866) 713-2399 or email us at support@modernblaze.com and we'll be happy to help.