Ndustria™ NBH Indoor/Outdoor Infrared U-Tube Gas Heater
Free delivery to contiguous U.S. + free 30-day returns. Est. arrival: Sep 6–16
Best Price Guarantee
Best Price Guarantee
- Lowest Price Online—Guaranteed. If you find the same product for less at another authorized dealer, we’ll beat it.
- Easy to Claim: click here to submit your price match request
- Qualifications: Item must be identical, in stock, new (not refurbished/open-box), and sold by an authorized dealer. Total cost (including shipping & tax) must be lower.
- Peace of Mind: All details you provide are kept completely confidential. We use this information only to verify the price.
Installation
Installation
Need installation support? We’ll help you find a qualified pro.
Request a Quote
Request a Quote
Need a price or shipping estimate? Click here to request a quote.
Photo Gallery
Description
Description
High-Bay Heat, Folded into a 22-Foot Run
A gas-fired low-intensity infrared tube heater with the burner tube folded back on itself, from Roberts-Gordon. Same equipment class that heats warehouses, manufacturing floors, hangars and service bays, in a shape that fits a shorter building.
Seven outputs, 60,000 to 150,000 BTU, in 12 ft 6 in to 22 ft 6 in. The straight-tube version needs 20 to 41 ft for the same outputs. If your clear run is short but your heat demand is not, this is the answer.
One correction worth making, because our own copy used to get this wrong: the U-tube does not produce more heat than the straight tube. Both reach 150,000 BTU. The U-tube reaches it in roughly half the length, and concentrates that heat over a tighter footprint. That is the actual difference.
Mounting height runs 10 to 12 ft on the smallest up to 20 to 25 ft on the largest. These are built for tall buildings, and infrared is why: it radiates onto the floor and the equipment instead of warming air that would collect uselessly at a 25 ft ceiling.
Vented or unvented. Unvented outdoors and under open cover. Indoors, vent through a 4 in flue or provide ventilation air, which code sets at a minimum of 4 CFM per 1,000 BTU/hr. A 150,000 BTU unit run unvented indoors needs 600 CFM, which is a real design decision rather than a footnote.
No square-foot rating is published for these. Roberts-Gordon sizes them from building heat loss and mounting height, and so do we. Tell us the building and we will help.
Natural gas or propane, direct spark ignition, CSA and ANSI certified, made in the USA.
Note: Covered and walled spaces, temporary or permanent, may need venting installed.
What's Included: U-Tube Heater, Reflector, and User's Manual
Do you live in places above 4,000 ft. elevation or need help determining the right heater and setup for your space and heating needs? Give us a call at (866) 713-2399 or email us at support@modernblaze.com and we'll be happy to